ENVIROMUX-1W
Low-Cost Environment Monitoring System – Supports up to 24 Temperature Sensors

ENVIROMUX-1W
Product Highlights
- 2 RJ11 connectors for daisy-chaining up to 24 single-reading 1-wire sensors
- 2 digital inputs for contact closure
- Power over Ethernet option
The ENVIROMUX® Environment Monitoring System with 1-Wire Sensor Interface (ENVIROMUX-1W) monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, web page, network management (SNMP), and/or SMS messages (via email-to-SMS).
The IoT system supports 24 single reading 1-wire sensors in any combination – temperature, humidity, dew point, thermocouple or digital inputs – and 2 separate digital inputs.
- Monitor and manage environmental and security conditions over IP.
- Sensors supported:
- 2 digital inputs sensitive to contact closure.
- 2 RJ11 6P4C connectors for daisy-chaining 1-wire temperature/humidity/dew point, thermocouple, or digital input expanders in any combination.
- Up to 24 temperature, thermocouple, or any single reading 1-wire sensor can be connected between both RJ11 connectors.
- Up to 8 temperature/humidity/dew point combination 1-wire sensors can be connected between both RJ11 connectors. Each temperature/humidity/dew point sensor is equivalent to 3 single reading sensors.
- Up to 12 E-DI2-1W digital input expanders can be connected between both RJ11 connectors to allow a maximum of 24 additional digital inputs. Each E-DI2-1W is equivalent to 2 single reading sensors.
- Maximum cable length supported on each connector is up to 600ft (183 m) depending on the configuration and number of connected sensors.
- Use RJ11 splitters (RJ11-3JCK) to daisy-chain 1-wire sensors (sold separately).
- Sensors are hot pluggable.
- The sensors will automatically be detected on power up or a Detect Devices button on the summary page can be selected when logged into the unit.
- Monitors (ping) up to 4 IP network devices – alerts are sent if devices are not responding.
- Sensor conditions can be configured to trigger alerts by themselves, and/or be used in combination with other alerts to trigger one Smart Alert.
- Supports 4 IP network video cameras for live view of any facility.
- Create multiple alerts for any installed sensor.
- Sensor conditions can be configured to trigger alerts by themselves, and/or be used in combination with other alerts to trigger one Smart Alert.
- Configure up to 32 alerts, and one Smart Alert.
- Dual redundant power supplies for connection to two separate power sources.
- The second power supply is sold separately.
- Available with optional Power over Ethernet (POE).
- Integrates with various Open Source SNMP monitoring packages – Nagios
- The unit can be polled via SNMP.
- Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors.
- Security: HTTPS, SSLv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
- Ideal for a wide range of applications including IT infrastructure monitoring, cold storage/freezer monitoring, or any unmanned area that needs to be monitored.
RJ11 Sensor Ports
- Two RJ11 6P4C jacks for daisy-chaining 1-wire temperature/humidity/dew point, thermocouple, or digital input expanders in any combination.
- Up to 24 temperature, thermocouple, or any single reading 1-wire sensor can be split between both RJ11 connectors.
- Up to 8 temperature/humidity/dew point combination 1-wire sensors can be split between both RJ11 connectors. Each temperature/humidity/dew point sensor is equivalent to 3 single reading sensors
- Up to 12 digital input expanders can be split between both RJ11 connectors to allow a maximum of 24 additional digital inputs. Each digital input expander is equivalent to 2 single reading sensors
- Maximum cable length supported on each connector is up to 600ft (183 m) depending on the configuration and number of connected sensors.
- This maximum includes the cable length of each sensor.
- RJ11 splitters or t-tap boards (RJ11-3JCK) for convenient daisy-chaining are sold separately.
Dry Contact Closures
- Two screw terminal pairs for connecting dry contact devices and liquid detection sensors.
USB Port
- One female Micro USB connector – reserved for future use.
Ethernet Port
- One female RJ45 connector.
- 10/100 Base-T Ethernet interface.
Protocols
- HTTP/HTTPS, SNMP V1/V2c, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSLv3, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour
- SSLv3 has been disabled in the following browser versions and affects HTTPS connection to the E-1W:
- Microsoft Edge
- Firefox Version 34 and newer
- Opera Version 25 and newer
- Google Chrome Version 40 and newer
- Internet Explorer and Safari: all versions allow SSLv3, if there are connection issues check if SSLv3 is manually disabled.
- SSLv3 has been disabled in the following browser versions and affects HTTPS connection to the E-1W:
- Compatible with any SNMP management software.
- The unit can be polled via SNMP.
- Operates and configures via HTTP/HTTPS web page.
- An IP address can be assigned to the E-1W automatically by a DHCP server.
- Generates SNMP traps, email alerts, syslog messages, and SMS messages (via email-to-SMS).
- Alerts are posted in event log, which is accessible through Web user interface.
- Email alerts can be sent to 9 addresses.
- Users can configure the schedule for when they will be alerted.
- Email alerts are not compatible with TLS.
Dimensions
- WxDxH in: 4×3.65×1.37 (102x93x35 mm).
Power
- E-1W:
- Dual DC power provides dual redundancy.
- If the first power source fails, the unit will automatically, without interruption, switch over to the second power source.
- The unit draws power from the source with the highest DC voltage (nominal 5.5V).
- If both sources have exactly the same voltage, it will draw in part from each of them.
- 110 to 240 VAC at 50 or 60 Hz via AC adapter.
- Includes one country-specific AC adapter. The second AC adapter is sold separately (PWR-SPLY-ELC).
- Input voltage: 5.5VDC ±5%
- Dual DC power provides dual redundancy.
- E-1WP:
- Built-in Power over Ethernet and dual DC power provides triple redundancy.
- Power over Ethernet standards supported: IEEE 802.3af, 802.3at.
- Proprietary schemes such as Cisco Discovery Protocol are not supported.
- Similar legacy switches and routers will have to use PWR-SPLY-ELC.
- Proprietary schemes such as Cisco Discovery Protocol are not supported.
- Power over Ethernet standards supported: IEEE 802.3af, 802.3at.
- If the first power source fails, the unit will automatically, without interruption, switch over to the second power source.
- The unit draws power from the source with the highest DC voltage (nominal 5.5V).
- If two or more sources have exactly the same voltage, it will draw in part from each of them.
- Built-in Power over Ethernet and dual DC power provides triple redundancy.
- 110 to 240 VAC at 50 or 60 Hz via AC adapter (not included).
- Country-specific AC adapters sold separately (PWR-SPLY-ELC).
- Input voltage: 5.5VDC ±5%
MTBF
- E-1W: 703,871 hours
Environmental
- Operating & Storage Temperature: -4 to 167°F (-20 to 75°C).
- Operating & Storage Relative Humidity: 0 to 90% non-condensing RH.
Regulatory Approvals
- CE, RoHS.
Web Interface
- Configuration can be done over the Internet/LAN via Web page.
- Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC.
- Configure sensor thresholds, alarm methods, formats of alerts, and system data log.
- View/edit sensors’ current values, thresholds and alert statuses.
- All sensors connected to the E-1W can be viewed on one summary page.
- User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert.
- The sensors will automatically be detected on power up or a Detect Devices button on the summary page can be selected when logged into the unit.
- View/edit entries stored in the system logs.
- Event log records system alerts.
- Stores up to 200 entries.
- Data log records samples of sensor readings per minute.
- Stores up to 43,000 entries per sensor.
- The data log can be downloaded as a comma-separated plain text file.
- Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings.
- Up to 9 users can access the web page at one time.
- Permissions, schedule and alert methods are configurable for each user.
- Configure up to 32 sensor conditions (alerts).
- Configure 1 Smart Alert to use different alert combinations to send alert messages.
Telnet
- Monitor over the text-based menu system accessible via Telnet.
- Access is controlled via username/password.
- System stores encrypted login information.
- Two user levels: user and administrator.
Network Operation
- SNMP support, allowing integration into network management platforms.
- Updating the system firmware.
Open Source Monitoring Integration
- Data Logging using Syslog
Optional Management Software
- Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors.
- Push configuration changes to multiple connected units in a group at once.
- E.g. new users, mail server, network settings, security settings, system settings, etc.
- Choose between Enterprise Management Software or Low-Cost Management Software.
- E-MNG Enterprise Management Software – use to monitor and configure up to 3,000 E-2D/5D/16D, E-MICRO-T(RHP), E-1W(P), E-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
- E-MNG-LC Low-Cost Management Software – use to monitor and configure up to 3,000 E-MICRO-T(RHP) and E-1W(P) units and all connected sensors.
Sensors & Accessories – Sold Separately
Environmental Sensors
- Temperature/Humidity Sensors
- K-Type Thermocouple Sensors
- Rope-Style Leak Detectors
- Spot Leak Detectors
- Under Carpet & Tape-Style Leak Detectors
- Smoke Detectors
- Gas Detectors
- Air Flow Sensor
Security Sensors
- Door Contact Sensors
- Vibration Sensor
- Glass Break Sensors
- Motion Detectors
- Tamper Switch
- Emergency/Panic Button
Communication Accessories
- IP Surveillance Cameras
Power Sensors
- AC Voltage Detector
Sensor Accessories
- 1-Wire Digital Input Expander
- RJ11 Splitter
- RJ11 Cables
- Self-Adhesive Clips for Liquid/Chemical Sensor Rope
- Surge Protectors
- Data Sheet