Select Page

ENVIROMUX-IPDU

Securely control power on/off/reboot to a server, router, web cam, firewall or other remote devices over IP.

ENVIROMUX-IPDU

Product Highlights

  • Power on/off/reboot
  • Configure up to 3 additional IP aliases that allow remote control of the unit through different networks
  • Linux inside
  • IPV 6 Compatible
  • Shut down power when high temperature and other threats detected

The ENVIROMUX® Secure Remote Power Control Unit allows you to remotely reboot and control power (on/off) to up to eight servers or other powered devices from any location via secure web interface, RS232, SSH, or Telnet.

  • Three operating modes for power reboot:
    • Manual – select the outlet and turn the power on/off.
    • Scheduled – set date/time/duration of power cycle.
    • Associated – power on/off a device when a sensor goes out of range of a user-defined threshold, or reboot unresponsive IP devices.
  • Security: HTTPS, SSHv2, SSLv3, TLS (4/8-port models only), IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
  • Configure, control and monitor the unit via Web interface or Command Line Interface (CLI).
  • Up to 3 additional IP aliases can be configured to allow remote control of the unit using different networks.
    • No scripts required – simply add the IP address, network mask, and gateway configurations through the web interface.
    • The first network (default network) will be used for total control of the unit, i.e. inbound and outbound connections.
    • The three other networks will allow web/SSH/telnet access only, i.e. inbound access only.
    • Up to four separate networks can be plugged into a network switch that is linked to the unit to facilitate the configuration.
  • Current, line voltage, line frequency, power factor monitoring (4/8-port models only).
  • Supports two environmental sensors, including: temperature/humidity and water detection.
    • Shut down power when high temperature and other environmental threats are detected.
  • Monitor (ping) up to eight IP network devices.
  • Sends alert notifications via email, syslog, LEDs, Web page, and SNMP.
  • Automatically configures network settings received from a connected DHCP server.
    • If a DHCP server is not found, the default static IP address will be used.
  • Integrates with various Open Source monitoring packages – Nagios and MRTG.
    • The unit can be polled via SNMP.
  • Up to 17 units can be connected via Ethernet connection or using CAT5 expansion cables to increase the number of outlets and sensors connected (4- and 8-port models only).
    • Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit via Ethernet connection.
      • Each master and slave unit needs its own unique IP address.
    • Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit using CAT5/5e/6 patch cables with RJ45 connectors wired straight through.
      • Each slave unit needs its own unique RS485 address value that can range from 1-255.
    • Uses a single Web interface for all systems/sensors connected.
  • Overload protection via circuit breaker (4/8-port models only).
  • Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 E-2D/5D/16D, E-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
  • Meets the electrostatic discharge (ESD) immunity requirements of IEC/EN 61000-4-2
  • Features Normally Open (NO) relay contacts.
    • The 4/8-port units are available with optional Normally Closed (NC) relay contacts.
  • Optional industrial unit for harsh environments at temperatures from -40° to 158°F (-40° to 70°C).
Power
  • 90 to 250 VAC at 50 to 60 Hz.
  • Input Connector:
    • IPDU-S2: IEC 320-C14 inlet
    • IPDU-Sx-P15(-OT3): NEMA 5-15P line cord (US)
    • IPDU-Sx-P10(-OT3): IEC 320-C14 inlet (EURO)
  • Output Connectors: IEC C13 outlets.
    • IPDU-S2: IEC 320-C13 outlets
    • IPDU-Sx-P15(-OT3): NEMA 5-15R outlets (US)
    • IPDU-Sx-P10(-OT3): IEC 320-C13 outlets (EURO)
Current Rating
NTI Part # Input/Output Location
IPDU-S2 10A All
IPDU-Sx-P15 15A US/Canada
IPDU-Sx-P10 10A Euro/UK
RJ45 Sensor Ports
  • Two RJ45 modular jacks for connecting NTI temperature/humidity and liquid detection sensors.
  • Available sensors
Network Interface
  • One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
Console Port
  • One female RJ45 port for terminal access.
Cascade In/Out Ports (4/8-Port Models)
  • Two RJ45 jacks.
  • A maximum of 17 systems can be used in a cascaded configuration via RS485 to increase the number of outlets and sensor ports (1 master, 16 slaves).
    • Each slave unit needs its own unique RS485 address value that can range from 1-255.
    • Use CAT5/5e/6 patch cables with RJ45 connectors wired straight through
    • Up to 1,000 feet between the master unit and the slave unit.
    • The last slave must have a terminating plug (E-TRMPLG, not included) in the empty socket.
USB Port (4/8-Port Models)
  • Female USB Type A connector for downloading log data to USB flash drive.
Environmental
  • IPDU-S2, IPDU-Sx-P15/P10:
    • Operating temperature: 32 to 122°F (0 to 50°C).
    • Storage temperature: -13 to 149°F (-25 to 65°C).
  • IPDU-Sx-P15/P10-OT3:
    • Operating temperature: -40 to 158°F (-40 to 70°C).
    • Storage temperature: -40 to 185°F (-40 to 85°C).
    • Operating/storage relative humidity: 0 to 90% non-condensing RH.
MTBF
NTI Part # MTBF (hrs)
IPDU-S2 183,724
IPDU-S4-P15 113,296
IPDU-S4-P10 86,017
IPDU-S8-P15 83,790
IPDU-S8-P10 57,051
Protocols
  • HTTPS, SSHv2, SSLv3, TLS (4/8-port models only), LDAPv3, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, SNMPv2c; IP filtering, IPV6
  • Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or RS232 interface.
  • Alerts are sent using email, syslog, and/or SNMP traps.
    • Alerts are posted in event log, which is accessible through Web user interface.
Regulatory Approvals
  • CE, RoHS
  • EN51055, EN50121-3-2
Web Interface
  • Configure, control and monitor via HTTP/HTTPS webpage.
  • Configure outlet operation settings, sensor thresholds and timing, alarm methods, alert formats, sensor/IP device outlet association, and system data log.
  • Add up to 3 additional IP aliases that allow remote control of the unit through different networks.
    • No scripts required – simply add the IP address, network mask, and gateway configurations through the web interface.
    • The first network (default network) will be used for total control of the unit, i.e. inbound and outbound connections.
    • The three other networks will allow web/SSH/telnet access only, i.e. inbound access only.
  • View outlet status, sensor values, IP device values, and alert status on one summary page.
    • View, Edit, Turn On/Off, Cycle buttons for each power outlet.
    • View and Edit sensors and IP devices.
  • View entries stored in the system logs.
    • Event log records system events such as alerts, user login/logout, failed email messages, etc.
    • Data log records samples of sensor readings. User specifies sampling time period.
    • The log can be downloaded as a tab-delimited plain text file.
  • Configure IP information, SMTP settings, SNMP settings, IP filtering, and user administrative settings.
  • Upload custom x509 certificates (4/8-port models only).
  • Administrate up to 15 users plus a root administrator.
  • Configure permissions, schedule and alert methods for each user.
  • Up to 17 units can be used together to increase the number of sensors connected.
    • Cascade up to 16 IPDU-Sx units as slaves to one IPDU-Sx master unit via Ethernet connection.
      • Each master and slave unit needs its own unique IP address.
    • IPDU-Sx slave units can also be configured as RS485 local slave units using CAT5/5e/6 patch cables with RJ45 connectors wired straight through.
      • Each slave unit needs its own unique RS485 address value that can range from 1-255.
      • The last slave must have a terminating plug (not included) in the empty socket.
    • Uses a single Web interface for all systems/sensors connected.
RS232/Telnet/SSH
  • Configure, control and monitor over the text-based menu system accessible via RS232, Telnet, and SSH.
  • Access is controlled via username/password.
    • System stores encrypted login information.
  • Two user levels: user and administrator.
Front Panel LED Indicators
  • “POWER” (green) – indicates device is powered.
  • “OUTLET” (green / red) – outlet is on or off.
  • “SENSOR FAULT” (red) – lights up if a sensor goes out of range of a configurable threshold.
  • “IP FAULT” (red) – lights up if an IP device is unresponsive.
Network Operation
  • Automatically configures network settings received from a connected DHCP server.
    • If a DHCP server is not found, the default static IP address will be used.
  • Integrates with various Open Source monitoring packages – Nagios and MRTG.
    • The unit can be polled via SNMP.
Open Source Monitoring Integration
  • SNMP Plugin for Nagios
  • NTI SNMP Plugin for Zabbix
  • Using Multi Router Traffic Grapher.
Optional Management Software
  • Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 E-2D/5D/16D, E-SEMS-16(U), IPDU-S4/8 units and all connected sensors.

  • Data Sheet